beautypg.com

Bryant PREFERREDT A07045 User Manual

Page 43

background image

43

the set button will cycle through the calendar, daily schedule, and vacation
settings.
Calendar may be changed by using the soft keys to select the Month, Day, or
Year. The UP/DOWN buttons are used to change the Month, Day, or Year setting

when the box surrounds it. Day of the week (Mon--Sun) is determined by

calendar settings and is not directly adjustable.
When changing daily schedule settings, the soft keys are used to set the days,

period times, heating setpoints, and cooling setpoints. The UP/DOWN buttons
are used to change the setting with the box around it. ALL PROGRAM

PERIODS (WAKE, DAY, EVE, SLEEP) MUST OCCUR WITHIN THE SAME

24 HOUR PERIOD.
When changing Vacation settings, the soft keys are used to choose the selection

to be adjusted and the UP/DOWN buttons are used to change the setting.
Humidify setting may only be changed when heat mode is selected and

Dehumidify setting may only be changed when cool mode is selected.

Humidity Control Features

The various humidity control features of the Thermidistat Control are explained
below. They are grouped into 2 sections, humidification and dehumidification.

Instructions on how to select each feature are given at the end of each section.

Humidification

The Thermidistat Control directly connects to a standard 24VAC humidifier to
control humidification in the home. A humidify setpoint between 10 and 46% in

2% increments relative humidity is selected by the homeowner, or all
humidification can be turned off. When humidity in home drops below setpoint,

humidifier will be turned on to raise humidity level. Humidification can only

occur while heating. See Table 2 for reference.

This manual is related to the following products: