ST-4125D/ST-6125D — 230/460 VAC VOLTAGE SELECTION

230/460 VAC Voltage Selection

The ST-4125D/ST-6125D submersible pump is factory set
at 230 VAC. To change the voltage from 230 VAC to 460
VAC, perform the following (refer to Figure 5):

1.

Place pump in a suitable area free of dirt and debris.

2.

Remove the four retaining screws, using a 19 mm socket,
and the two Allen screws using an 8 mm socket, that secure
the pump casing.

3.

Lift the top of the pump by attaching a chain on the eye
bolts and using a crane or similar equipment. Be careful
not to fully stretch the cable connections inside the pump.

4.

Cut the tie-wrap holding the 460 VAC motor winding wires
as shown in Figure 5. Then remove the protective covering
from the wires (labeled 4, 5, and 6).

5.

Remove the sleeving covering the large red wire and
separate the 2 wires labeled 1 and 7.

6.

Connect the wire labeled 4 from step 4 to the wire labeled
7 from step 5 and join them with the large red wire. Cover
the wires with sleeving.

7.

Repeat steps 5 and 6 for the large black wire and the large
white wire. Refer to the table in Figure 5 for wires to separate
(column 2) and wires to connect (column 4).

8.

Using electrical tape, bind the 3 wires that were separated
and disconnected (labeled 1, 2, and 3). Place these wires
neatly inside the housing.

9.

Reinstall the top of the pump and reinsert the six screws
and tighten securely.

Figure 5. 230/460 VAC Pump Voltage Selection

3

9 8

7

1 2

4

5

6

BLACK

9

3

RED

WHITE

(LARGE)

GREEN

2

1

8

7

230 VAC

MOTOR

WINDINGS

230/460 VAC

MOTOR

WINDINGS

COMMON

4

5

6

460 VAC

MOTOR

WINDINGS

WHITE

(SMALL)

BLACK

(SMALL)

BLACK

(SMALL)

W

Z

X

Y

V

9

8

U

7

MOTOR

WINDING

STAR WITH

NEUTRAL

230 VAC

(LOW VOLTAGE)

460 VAC

(HIGH VOLTAGE)

MOTOR

WINDING

STAR WITH

NEUTRAL

9

W

Z

8

Y

V

7

X

U

REMOVE PROTECTIVE

COVERING TO GAIN

ACCESS TO 460 VAC

WIRES 4, 5, AND 6.

REMOVE SLEEVING

230 VAC

INPUT 3Ø

U (RED)

V (WHITE)

W (BLACK)

MOTOR

WINDINGS

1 AND 7

2 AND 8
3 AND 9

460 VAC

INPUT 3Ø

U (RED)

V (WHITE)

W (BLACK)

MOTOR

WINDINGS

4 AND 7

5 AND 8
6 AND 9

MOTOR WINDING CONFIGURATION

NOTE

PUMP IS SHIPPED FROM THE FACTORY FOR 230 VAC OPERATION.
FOR 460 VAC OPERATION SEE ABOVE WIRING ILLUSTRATION AND TABLE.

CONNECT

TO GROUND

SCREW IN

UPPER CASING

CUT

TIE-WRAP

This manual is related to the following products: