FLOAT SWITCHES

Float Switch Theory

There is a tilt-sensitive mercury switch hermetically sealed within
each float. As the liquid level (water) rises or falls, the float changes
its angle until the mercury switch makes (close) or breaks (open)
the circuit.

The length of cord between the float and point of attachment
determines the amount of water to be pumped.

Figure 3. Dual Float Control Switch

Float Switch (Dual)

Float switches (Figure 3) are used for the unattended operation
of the submersible pump. The ST-4125D and ST-6125D pumps
require the use of a control box to perform this function. Shown
in Figure 3 is an example of a dual float control switch application.

The Models ST-4125D and ST-6125D submersible pumps
require one each of the Model SW-1WOPA float type mercury
switches. These switches have a pumping range level between
5.5~18 feet (1.67~5.5 meters). All float switch connections are
bare wire (no plug). The ST-4125D/ST-6125D uses the

CB12

control box for 230V

and the

CB14 control box for 460 V

when float switches are required for the job application.

Contact Multiquip sales department to order float switches.

CONTROL

BOX

EXTERNAL 3-PHASE

(230 OR 460 VOLT)

POWER SOURCE

CIRCUIT

BREAKER

RED

WHITE
BLACK

L1

L2

L3

GREEN

GROUND

SUBMERSIBLE

PUMP

ST-6125D

LIFTING

CHAIN

4 or 6-INCH

DISCHARGE

HOSE

POWER

CORD

SUPPORT

PLATFORM

LOW

ER

PUMP

ON

PUMP

OFF

FLOAT

SWITCHES

CAUTION!

HIGH

VOLTAGE!

CAUTION!

HIGH

VOLTAGE!

CB12/14

RESET

This manual is related to the following products: