beautypg.com

1 introduction – Bosch AQ4 GWH 1600 P User Manual

Page 3

background image

3

AQ4 Manual

1 Introduction

1.1 Parts included

Vent Hood Kit
• 1 - 4” vent hood: VH1-4

• 4 - Exterior screws

• 1 - 5” to 4” vent reducer pipe
Vibration Mount Packet
• 2 - Vibration mounts with nuts and washers

• 2 - Brackets with nuts and washers
Flow Switch Packet
• 1 - Flow switch

• 4 - Replacement pipes (See chapter 2.7)

• 2 - Pipe clips

• 1 - Molex connector cable

• 1 - Heat exchanger bushing
Power vent motor
• 1 - Power vent motor (HSUL-1 Series containing

integrated 24v control circuit) including 25 foot

control cable with wire nuts and an HPN 6-foot

power cord

• 5 - Nylon ties

1.2 Warnings

1. Failure to install, maintain and/or operate the

power vent in accordance with manufacturer’s

instructions may result in conditions which can

produce bodily injury and property damage.

2. The power vent must be installed by a qualified

installer in accordance with all local codes or, in

their absence, in accordance with the National

Fuel Gas Code (ANSI Z223.1 NFPA #54), the

National Electric Code, the Canadian Electrical

Code (C22.1), Canadian Gas Code (CSA B149.1)

and The Occupational Health and Safety Act

(OSHA) as applicable.

3. The power vent motor shaft must be mounted

horizontally to prevent motor bearing wear.

4. Disconnect power supply when making wiring

connections or when working around the fan

blade and motor. Failure to do so may result in

severe personal injury and equipment damage.

5. Make certain the power source is adequate for

the fan motor requirements. Do not add the

power vent to a circuit where the total load is

unknown.

AQ4 Motor is 200 watts- 1.66 amps @ 120vac.

6. Locate the outlet receptacle as close to the vent

motor as possible. Do not use an extension

cord.

Warning: If the back draft flapper on the

vent hood does not close properly, it may

allow freezing air to come in contact with

the water heater’s heat exchanger and

cause the heat exchanger to burst. Such

damage is not covered under the water

heater’s warranty.

1.3 Preparation

1. Follow installation and operating instructions

manual supplied with the water heater.

2. Before mounting water heater to wall, check its

minimum clearance requirements.

3. When using an AQ4 the maximum vent length

from the water heater to the point of termination

is 25 feet with one elbow. Subtract 5 feet for

each additional 90° elbow (up to two additional

elbows allowed.)

4. Install power vent motor as close to the vent hood

as possible.

Introduction