Operation – AEG Charger LK 1204 User Manual
Page 24

24
oPeraTIon
Before charging batteries
▪
If the battery must be removed from the vehicle before charging, always discon-
nect the earthed connector from the battery first also ensure all other loads in
the vehicle are off
▪
ensure adequate ventilation to allow any toxic vapours or gasses to disperse
▪
ensure the battery poles are clean If the battery has a removable vent cap, fill
each battery cell with distilled water to the manufacturer recommended level do
not overfill the cells
▪
If the battery does not have caps, refer to the manufacturer instructions on char-
ging and the charging speed
Connecting the battery
Risk of electrical shock!
always verify the charging device is disconnected from the 230 V aC
outlet when connecting to a battery
▪
always ensure the area around the battery is well ventilated during the charging
process
1 Connect the positive charging clamp (red) to the positive battery terminal
(marked P or +)
2 Connect the negative charging clamp (black) to the body of the vehicle, or in
exceptions to the negative battery terminal (marked n or -)
3 Verify both terminal clamps make good contact with the respective terminals
4 Plug the power plug into a suitable aC mains outlet
In the event of reverse polarity all four leds will light up
Charging will not start