Cabling – Alloy Computer Products RNS5 User Manual
Page 11
![background image](/manuals/47828/11/background.png)
Fig C Straight Through Cabling Schematic Fig C-1 Cross Over Cabling Schematic
All ports of RNS5/8 support the auto-MDI/MDI-X function. When you use an
Ethernet cable to connect other devices, such as computers, switches or hubs, pin
1, 2, 3, and 6 of the 8-pin RJ45 connector are used to communicate with the
connected devices. Pin1, 2, 3, and 6’s signals are converted by the MDI-X function,
as shown in Table 2.
Pin MDI-X
Signals
MDI Signals
1 RD+
TD+
2 RD-
TD-
3 TD+
RD+
6 TD-
RD-
Table 2
Cabling
The cable connection between the RNS5/8 and the attached devices (switches,
hubs, workstations, etc.) must be less than 100 meters (328 ft.) long.
9