Konica Minolta bizhub C450P User Manual
Page 26
Administrator Operations
2
C450P
2-9
Ad
minist
ra
to
r Op
er
at
ions
Chapter 2
Setting the EnhancedSecurity mode to “ON” changes the setting values of
the following functions.
2
Reminder
When Password Rules is set to “Enable,” the characters and the number
of digits used for each password are restricted. For details of Password
Rules, see “Password Rules” on page 1-11.
Function Name
Factory Setting
When EnhancedSecurity mode is set to [ON]
Password Rules
Disable
Enable (not to be changed)
Prohibit Setting
Mode 1
Mode 2 (not to be changed)
Three times is set.
* In association with Secure Document Access
Method, the method is changed from authenti-
cation using Secure Document ID and pass-
word (Mode 1) to that using the password with
the secure document first narrowed down by
Secure Document ID (Mode 2).
SSL
OFF
ON (not to be changed)
FTP Server
ON
OFF (not to be changed)
SNMPv1/v2c
Read/Write en-
abled
Only Read is enabled (not to be changed)
SNMP v3 Security Level
and auth/priv-password
auth/priv-pass-
word
The security level can be selected from among
“auth-password” and “auth/priv-password.”
An 8-digit-or-more auth-password and priv-
password can both be set.
Data Capture
Permit
Prohibit (not to be changed)
Network Setting Clear
Enabled
Restrict
c450P_security_E.book 9 ページ 2007年4月10日 火曜日 午後6時49分