• If the voltage is not correct, replace the ac power adapter.
• If the voltage is acceptable, do the following:
a. Replace the system board.
b. If the problem persists, call the Customer Support Center.
Note: Noise from the ac power adapter does not always indicate a defect.
Checking operational charging
To check whether the battery pack charges properly during operation, do the following:
Note: Before you begin, install a discharged battery pack or a battery pack that has less than 50% of the
total power remaining in the computer.
1. If the battery status indicator does not turn on, remove the battery pack and let it return to room
temperature.
2. Reinstall the battery pack.
3. If the indicator still does not turn on, replace the battery pack.
4. If the indicator still does not turn on, replace the system board. Otherwise, refer to “Checking the battery
pack” on page 29to check the original battery pack.
Checking the battery pack
The battery status icon in the Microsoft
®
Windows
®
notification area displays the percentage of battery
power remaining.
To check detailed battery status information on the Windows operating systems, launch the Power Manager
program and click the Battery tab.
To check the battery pack, do the following:
1. Turn off the computer and disconnect the ac power adapter.
2. Remove the battery pack and measure the voltage between battery terminals 1 (+) and 7 (-). The
correct voltages are shown in the following table.
Terminal
Voltage (V dc)
1
+ 0 to + 14
7
Ground (-)
1(+)
2(+)
5
4 3
6(-)
7(-)
3. Measure the resistance between battery terminals 5 and 7. The resistance should be 4 to 30 KΩ. If the
resistance is not correct, replace the battery pack.
4. Depending on the voltage that you measure, do one of the following:
• If the voltage is less than +12.0 V dc, recharge the battery pack. If the voltage still is less than +12.0 V
dc after recharging, replace the battery pack.
• If the voltage is more than +12.0 V dc, discharge the battery pack until the voltage becomes less
than +12.0 V dc and then recharge the battery pack. If the voltage still is less than +12.0 V dc after
recharging, replace the battery pack.
Note: Recharging will take at least three hours, even if the battery status indicator does not turn on.
5. Replace the system board if the new battery pack is not charged.
Chapter 2
.
General checkout
29