Omnireach, Ncx-1000s, Distribution intercept cross-connect for coolped – ADC OmniReach NCX-1000s User Manual
Page 3: Cabinets, Specifications, Cross box dlc remote cabinet

6/08
•
104982AE
OmniReach
®
NCX-1000s
OmniReach
®
NCX-1000s
Distribution Intercept Cross-Connect for CoolPed
™
Cabinets
3
w w w . a d c . c o m
•
+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0
•
1 - 8 0 0 - 3 6 6 - 3 8 9 1
Benefits
Can be deployed in feeder or distribution
•
outside plant cable, the most flexible
solution available
Fastest to deploy, only straight splicing
•
activities to OSP required
Unique look-both-ways test capability without
•
lifting wires reduces time for technicians to
isolate network problems
Distribution Intercept (DI) offers the most
•
streamlined approach to xDSL delivery
Cross Box
DLC Remote Cabinet
CoolPed Cabinet
NCX-1000s cross connect in CoolPed
•
Central location for xDSL service delivery
•
LSA-PLUS IDC for distribution intercept
•
“Look both ways” testing
•
DLC Remote Cabinet
Cross Box
Specifications
GENERAL SPECIFICATIONS
Mounting:
Bracket included for CoolPed™ cabinet
with mounting rails
DSLAM Ports In/Out:
48 to 144
OSP Intercept Pairs In/Out:
100 to 600 pairs
Cabling:
OSP gel filled direct bury cable with raw
ended stubs 12 ft in length
Accessories:
Includes Insertion Tool and LSA-PLUS Series 2
green plugs for xDSL activation
MECHANICAL SPECIFICATIONS
OSP Input/Output:
LSA-PLUS Series 2 disconnect block (white)
DSLAM Input/Output:
LSA-PLUS Series 2 switching block (brown)
Contact Resistance:
< 1 m Ω
Insulation Resistance:
> 5 x 104 MΩ
Contact Material:
Copper Alloy
Contact Plating:
Silver
Number of Test Cord Insertions:
> 750
IDC Reterminations:
> 200
Cross Connect Wire Requirements:
24 AWG solid, tinned cross connect wire
for all terminations