2
S
AFETY DEVICES
DO NOT ALTER THE SAFETY DEVICES AND DO NOT OPERATE THE MACHINE IF THE SAFETY DE-
VICES ARE DAMAGED OR MALFUNCTIONING.
THE MANUFACTURER IS NOT RESPONSIBLE FOR POSSIBLE DAMAGE OR INJURY CAUSED BY AL-
TERING OR BYPASSING SAFETY DEVICES OR RELATIVE CIRCUITS.
2.1
Magnetic sensor
This safety device, composed of an approved magnet [1] and of a magnetic contact
[2] is designed to prevent the stirrer from starting accidentally. There fore, this machine
will not work without a magnet. If the magnet [A] or the rotor lid [B] are removed, the
stirrer stops working immediately.
DURING NORMAL OPERATIONS, THE MACHINE MUST BE STOPPED
ONLY BY THE APPROPRIATE KEYS ON THE CONTROL KEYBOARD.
3
T
ECHNICAL DATA
3.1
Technical data plate and marking
The technical data plate and marking must not be removed. It is placed on the back side of the device and identifies:
-
the name and address of the manufacturer [1];
-
the designation of the model [2];
-
the relative serial number [3] and the year of construction [4];
-
the voltage and frequency rating [5];
-
the type of cooling [6], the power [7] and current [8] consumption;
-
the type and quantity of refrigerant gas used [9];
-
refrigerant pressure specification [10].
3.2
Acoustic decibal rating
The average equivalent continuous acoustic of this device is quoted in the Technical Handbook (Technical Data section).
This data has been measured at 1 meter (40") from the surface of the device and at 1. 60 meters (630") from ground- level,
during the device’s functioning.