HEATING/COOLING Pushbutton [K5]
On pressing the button a complete and automatic heating/cooling mixing cycle is set in motion. Once finished, the machine
goes into ageing mode. For further details see Par. 6. 3 - heating/refrigeration cycle.
The [Z5] light remains on until the command has been removed.
SLOW BEATING button [K6]
On pressing the button, the relative light [Z6] comes on and the beater operates CONTINUOUSLY AT LOW SPEED. This
command can also be activated during the heating/cooling and preservation cycle. When the button is pressed again, the
beater stops and the light turns off.
MANUAL REFRIGERATION/PRESERVATION Pushbutton [K7]
When the pushbutton’s indicator [Z7] is on, the machine is in preservation mode: the mixture inside the tub is maintained
at a temperature of approximately 4°C/40°F (or the final preset temperature). The beater, starting at the same time as the
refrigerator, shifts the mixture to keep it homogenous and to maintain a uniform temperature.
To manually activate (light on) or deactivate (light off) the preservation mode, or to interrupt the heating phase during the
heating/cooling cycle and to start the cooling process, simply press this button.
SET UP Pushbutton [K8]
The main heating/cooling and preservation cycle values can be viewed on the display by pressing this button. They can
be adjusted (where necessary) by pressing [K2] and [K3]. For further instructions see Par. 6. 3 and 6. 4 - Programming
WASH Pushbutton [K9]
When pressing, the automatic washing of the tap commences. See also Par. 6. 5 “Washing the tap”.
Digital Display
When turning on and during regular functioning, the display always shows the temperature inside the tank (together with
that of the mixture inside);
-
During set up, the display shows current settings;
-
If “
ooo” (three small squares) appear, the impeller cover with it's polarized magnet is not correctly placed, or the
beater motor protection has been activated.