4.1 LIGHT INDICATORS

The machine has two lights that will alert the user if a problem occurs: an ADD MIX light and a Diagnostic Light.

The ADD MIX light will fl ash to alert the operator to a low mix condition. It does so by monitoring the mix level in the
hopper. When the ADD MIX light is fl ashing, refi ll hopper immediately.

The Diagnostic Light will fl ash if an error occurs. Refer to the chart below for details.

4.2 TROUBLESHOOTING

Indication

On

One Blink

Two Blinks

Three Blinks

Conditions

Defrost Mode

Torque is not

met after 20

minutes

(22 minutes for

shake)

Drive current is not sensed

Machine left in clean

mode for over 20

minutes

Self
Correction

N/A

N/A

The machine attempts to sense drive

current with a 3 second pre-stir. If

current is sensed, the machine will return

to normal operation. If current is not

sensed, the machine will wait 7 minutes

and try to sense current with another 3

second pre-stir. After the third attempt,

the compressor will run on timers.

N/A

Operation

Every 7 minutes

the auger will

run for 90

seconds.

Timers or until

torque switch

remains closed

for 3 seconds.

Timers

Off

Corrective
Action

N/A

Contact Service

Technician

Contact Service Technician

Turn CLEAN-OFF-

ON switch to OFF

(middle) position then

turn the switch to ON.

PROBLEM

POSSIBLE CAUSE

REMEDY

Machine does not
run.

1. Power to machine is off.
2. Blown fuse or tripped circuit.
3. Freeze-up (auger will not turn).

4. High pressure cut-out tripped.
5. Front door not in place.

1. Supply power to machine.
2. Replace or reset.
3. Turn CLEAN-OFF-ON switch to OFF (middle)
position for 15 minutes, then restart.
4. Wait until automatic reset for machine to start.
5. Assemble front door in place.

Machine will not
shut off.

1. Drive belt failure.
2. Consistency temperature setting is too
fi rm.
3. Refrigeration problem.

1. Replace drive belt.
2. Turn Consistency Adjustment knob counter-
clockwise.
3. Check system. (Call distributor for service)

Product is too fi rm.

1. Consistency temperature
setting is too fi rm.

1. Turn Consistency Adjustment knob counter-
clockwise.