Vollrath Signature Server Hot Food Base with Touch-Temp Panel Installation Instructions User Manual
Page 2

2
6. Locate the slide switches (A) at the center of the Logic Board, located on
back side of Control Panel. Using a ball point pen, slide the switch for each
well in the Serving Station to the ON (up) position. Slide all unused switches
to the OFF (down) position. See Figure 3.
B
A
Figure 3. Logic Board
Note: These well numbers must match the well numbers being used on the
Relay Board.
7. Plug the other end of Ribbon Cable into socket on Logic Board port (B). The
connector is keyed and will only fit into the socket in one direction.
8. Check all connections to make sure they match Figure 2 and Figure 3.
9. Install Control Panel using (2) screws removed earlier.
t
esting
and
C
heCking
o
PeRation
1. A continuity check is recommended at the power plug to make sure there is
no short circuit.
2. Plug in the power cord into the outlet to reconnect power.
See Operating Instructions, below.
NOTE: Low Water Indicator will not function on older Signature Server Hot
Stations that do not have a low water sensor (sensor cannot be retrofitted).
Turn the unit ON/OFF:
1. Press and hold the ON/OFF button for 2 seconds to turn the entire unit ON
or OFF. The wells will automatically be set to the previous well settings.
If the lights flash “8” check the Ribbon Cable to make sure it is seated
correctly.
2. Set Individual Wells:
3. Push and hold arrows for each well until desired heat setting is displayed in
the well display window.
The heat settings range between 0 and 9: 0 = OFF------------------ 9 = HIGH
Low Water Indicator:
The low water light will not illuminate when the unit is initially turned on. The low
water light will only indicate when water is needed during operation. The low
water sensor is located in the #1 well (well furthest to the left when facing the
controller) and therefore will only operate if the first well is used.
NOTE: Located in the bottom right corner of each well display, an illuminated
dot will appear when the element has cycled on and is heating.
www.vollrathco.com
The Vollrath Company, L.L.C.
1236 North 18th Street
Sheboygan, WI 53081-3201
U.S.A.
Main Tel: 800.628.0830
Fax: 800.752.5620
Technical Services: 800.628.0832
Service Fax: 920.459.5462
Canada Service: 800.695.8560
© 2011 The Vollrath Company, L.L.C.