6. Locate the slide switches (A) at the center of the Logic Board, located on

back side of Control Panel. Using a ball point pen, slide the switch for each

well in the Serving Station to the ON (up) position. Slide all unused switches

to the OFF (down) position. See Figure 3.

B

A

Figure 3. Logic Board
Note
: These well numbers must match the well numbers being used on the

Relay Board.
7. Plug the other end of Ribbon Cable into socket on Logic Board port (B). The

connector is keyed and will only fit into the socket in one direction.

8. Check all connections to make sure they match Figure 2 and Figure 3.

9. Install Control Panel using (2) screws removed earlier.

t

esting

and

C

heCking

o

PeRation

1. A continuity check is recommended at the power plug to make sure there is

no short circuit.

2. Plug in the power cord into the outlet to reconnect power.

See Operating Instructions, below.
NOTE: Low Water Indicator will not function on older Signature Server Hot

Stations that do not have a low water sensor (sensor cannot be retrofitted).
Turn the unit ON/OFF:
1. Press and hold the ON/OFF button for 2 seconds to turn the entire unit ON

or OFF. The wells will automatically be set to the previous well settings.

If the lights flash “8” check the Ribbon Cable to make sure it is seated

correctly.

2. Set Individual Wells:

3. Push and hold arrows for each well until desired heat setting is displayed in

the well display window.

The heat settings range between 0 and 9: 0 = OFF------------------ 9 = HIGH
Low Water Indicator:
The low water light will not illuminate when the unit is initially turned on. The low

water light will only indicate when water is needed during operation. The low

water sensor is located in the #1 well (well furthest to the left when facing the

controller) and therefore will only operate if the first well is used.
NOTE: Located in the bottom right corner of each well display, an illuminated

dot will appear when the element has cycled on and is heating.