Add pan, Bad pan, Too hot – Vollrath Mirage Drop-In Induction Warmers 11 Qt User Manual
Page 4: Bad flo, Ht snc, Ht th, English, Warning

O
peratOr
’
s
M
anual
4
ENGLISH
t
roubleShooting
Problem
It might be caused by
Course of Action
The unit is on, but not heating.
The inset may be too small or may not be induction-
ready.
Make sure the inset is induction ready. See the
FUNCTION and PURPOSE of this manual.
The digital display lights are flashing.
Alarm buzzer is sounding.
No induction-ready inset in unit.
Place induction-ready inset in the unit.
The unit suddenly stopped working.
The unit may be too close to an external heat source
or the air intake may be restricted.
Relocate the unit away from any external heat
source. Clear any obstructions to the air intake.
The overheat-protection feature may have activated. Remove inset. Let cooking surface cool.
Flashing Message (F code)
It might be caused by
Course of Action
Add Pan
(Add Pan)
No inset has been detected on the induction
rethermalizer
Place induction-ready inset in the heating area..
Bad Pan
(Bad Pan - F9)
The inset may be too small or is not a Vollrath
induction-ready inset.
Turn the unit “OFF” and “ON”. Use a Vollrath
induction-ready inset. See the FUNCTION and
PURPOSE of this manual.
TOO HOT
(Too Hot - F2)
The overheat-protection feature may have activated. Remove inset. Let cooking surface cool. Clear any
obstructions to the air intake.
BAD FLO
(Bad Flow - F8)
The unit may be too close to an external heat source
or the air intake may be restricted.
Relocate the unit away from any external heat
source. Clear any obstructions to the air intake.
HT SNC
(Heat Sync - F4)
The overheat-protection feature may have activated. Remove inset. Let cooking surface cool. Clear any
obstructions to the air intake.
HT TH
(Heat Therm - F5)
The overheat-protection feature may have activated. Remove inset. Let cooking surface cool. Clear any
obstructions to the air intake.
HOT
No defect. This is part of normal operation.
Indicates the heating area is hot after a heating cycle
has completed. Allow time for the heating area to
cool (about 5-10 minutes) before cleaning.
WARNING
Electrical Shock Hazard.
Keep water and other liquids from entering the
inside of the unit. Liquid inside the unit could cause
an electrical shock.
Do not spray water or cleaning products. Liquid could contact the
electrical components and cause a short circuit or an electrical
shock.
1. Unplug the unit and let it completely cool.
2. Wipe the unit exterior with a clean damp cloth.
NOTE:
Do not put water in the warmer/rethermalizer. It is intended to run
dry. Water will damage the unit and void the warranty.
3. Wipe the inside of the unit with a clean damp cloth.
4. Do not use abrasive materials, scratching cleansers or souring pad to
clean the unit. These can damage the finish.
5. Thoroughly wipe off any mild soap or chemical cleaners. Residue could
corrode the surface of the unit.