CALIBRATION INSTRUCTIONS

THIS SCALE IS ACCURATE WITHIN 0.1g, only calibrate if your readings are

inaccurate beyond 0.1g. Allow your scale to warm up for several seconds

before calibration. Always move your hands very gently during calibration as to

not cause vibrations or air movement.

1. PLACE THE SCALE ON A FLAT SURFACE THAT HAS NO VIBRATIONS

AND MAKE SURE THERE IS ABSOLUTELY NO AIR MOVEMENT.

(SURFACE MUST BE EXTREMELY STABLE).

2. TURN THE SCALE OFF AND CLEAR THE PLATFORM (MAKE SURE

NOTHING IS ON THE PLATFORM).

3. TURN THE SCALE ON BY PRESSING THE ON KEY. WHEN THE

DISPLAY SHOWS 0.0, WAIT 5 SECONDS.

4. PRESS AND HOLD THE ON KEY FOR 3 SECONDS UNTIL IT SHOWS “0”,

THEN RELEASE THE KEY.

5. IT WILL THEN SHOW “300.0”. THE UNIT “g” WILL KEEP FLASHING.

ADJUST THE FIGURE USING THE TARE KEY IF NECESSARY, (e.g.

CHANGE TO 100.0 for 100g CALIBRATION). PLACE THE

CORRESPONDING WEIGHT (e.g. 100g) ON THE CENTER OF THE

PLATFORM AND WAIT FOR 5 SECONDS.

6. THE SCALE WILL SHOW “100.0” AND THE UNIT “g” WILL STOP

FLASHING AFTER THE CALIBRATION IS COMPLETE.

IF THE READINGS ARE INACCURATE, PERFORM CALIBRATION AGAIN.

IF YOUR SCALE WILL NOT PROPERLY CALIBRATE OR SHOWS “ERR”

PLEASE VISIT OUR WEBSITE FOR ADVANCED CALIBRATION &

TROUBLESHOOTING INSTRUCTIONS

BATTERY INSTRUCTIONS

USE TWO AAA BATTERIES. PLEASE MAKE SURE THE POLARITY IS

CORRECT WHEN INSTALLING NEW BATTERIES. LOW BATTERIES ARE

THE #1 CAUSE OF SCALE MALFUCTION SO BE SURE YOUR BATTERIES

ARE GOOD.