beautypg.com

MyWeigh HD SERIES User Manual

Page 4

background image

Data bits : 8 bits

Stop bit : 1 bit

Parity : none

When work mode “SCI.3” is selected and the scales “DATA” key is pressed or the carriage return

(0d hex) is received, the HD shipping scale will transmit the appropriate weight, unit, stability,

over/down or low voltage message through computers serial port continuously.

Baud rate : 9600bps

Start bit : 1 bit

Data bits : 8 bits

Stop bit : 1 bit

Parity : none

(2) The scale transmits 14 bytes ASCII data each time:

The details are as follows:

Byte1. :” (colon), starting byte

Byte2. “W” the following 7 bytes (3 through 9) are weight;

M the following 7 bytes (3 through 9) are messages

Byte3. “- “ Byte 4 through Byte 9 are negative weight;

” Byte 4 through Byte 9 are positive weight or other message

Byte4. Current weight or other message

Byte5. Current weight or other message

Byte6. Current weight or other message

Byte7. Current weight or other message

Byte8. Current weight or other message

Byte9. Current weight or other message

Byte10.11. “lb the weight unit is lb;

kg” the weight unit is kg

Byte12. “S” the readings are stable;

” the readings are unstable

Byte13. “L” low voltage

” normal voltage

Byte14. Carriage Return (0d hex)

(3) RS-232 connect between HD scale and Host :

Scale--------------------------Cable-----------------------Host

(DB9 female)-----------(DB9 male)-(DB9 female)-------(DB9 male)

TXD 2----------------2------------------2-------------2 RXD

RXD 3----------------3------------------3-------------3 TXD

GND 5----------------5------------------5-------------5 GND

DSR 4----------------4------------------4-------------4 DTR

DTR 6----------------6------------------6-------------6 DSR

CTS 7----------------7------------------7-------------7 RTS

RTS 8----------------8------------------8-------------8 CTS

NC 1----------------1------------------1-------------1

NC 9----------------9------------------9-------------9

***Note: HD scale DB9 female’s pin4 and pin6 is shorted, pin7 and pin8 is shorted!