1.
Tested at nominal input voltage, nominal input frequency and without a dimmer after soaking for 15 minutes
2.
Average
3.
Peak-to-peak
4.
Measured with Chroma 66202 Power Analyzer
5.
This document includes trademarks, trade names, brands, logos, product names and/or product identifiers of companies other
than Cirrus Logic, Inc. All such trademarks, trade names, brands, logos, product names, and product identifiers are for
identification purposes only and are the property of their respective owners, who are not affiliated with Cirrus Logic. Please visit
the respective sites of those owners to obtain a listing or understanding of their trademark rights. This document also includes
results from testing performed by Cirrus Logic for its own purposes and for which there are currently no industry standards. While
this testing was applied objectively, its results may include at least some degree of subjectivity. The testing or test results should
not be interpreted as any comment on the overall quality or suitability of any tested products
N&L 28985
Trailing Edge
Y
Y
Y
Y
Y
N
292
280
129
6
6
129
Opus 852.390
Leading Edge
Y
Y
Y
Y
Y
Y
298
298
298
25
25
25
Opus 852.392
Leading Edge
Y
Y
Y
Y
Y
Y
298
298
298
6
6
6
Songri 400W
Leading Edge
Y
Y
Y
Y
Y
Y
297
297
298
6
6
6
T&J K211-1KM2
Leading Edge
Y
Y
Y
Y
Y
Y
476
475
NA
9
12
6
T&J K211-M2
Leading Edge
Y
Y
Y
Y
Y
Y
297
297
298
6
6
6
TCL LM2
Leading Edge
Y
Y
Y
Y
Y
Y
297
297
298
6
6
6
TNC Z26-M12
Leading Edge
Y
Y
Y
Y
Y
Y
298
298
298
6
6
6
Wuyun W13-C162
Trailing Edge
Y
Y
Y
Y
Y
Y
298
300
300
6
6
6
Dimmer
5
Flicker Free
Steady-State
Monotonic
Dimming
Max I
out
(mA)
Min I
out
(mA)
Manufacture
Type
# of lamps
# of lamps
# of lamps
# of lamps
1
5
10
1
5
10
1
5
10
1
5
10