beautypg.com

errata, Errata, Cdb4364 – Cirrus Logic CDB4364 User Manual

Page 5

background image

DS619DB1

5

CDB4364

Table 2. CDB4364 Jumper Settings

*Default Factory Settings.

8. ERRATA

CDB4364 rev C:

-None at this time.

JUMPER /

SWITCH

PURPOSE

POSITION

FUNCTION SELECTED

J15

Selects source of control

data

*shunts on Left

shunts removed

*Control from PC and on-board microcontroller

External control input using center and right columns

J16

JTAG micro programming

-

Reserved for factory use only

S2

Resets CS8416 and

CS4364

The CS8416 must be reset if switch S1 is changed

S1

CS4364 mode settings M0-

M4

1-5

Default: M0, M4 open (HI)

M1, M2, M3 closed (LO)

Sets clock source

6

Sets clock source for CS4364

*open = RX(CS8416), closed = EXT(J11)

Sets MCLK ratio of CS8416

7

Selects 128x (open) or 256x (*closed) MCLK/LRCK

ratio output for CS8416

Selects PCM or DSD mode

8

For PCM input set to *Open, for DSD set to Closed