CRD1611-8W

DS975RD5

23

9. CONDUCTED EMI

Device Under Test: CRD1611-8W-Z

Operating Conditions: NOMNIAL

Test Specification: IEC 61000-3-2

Operator Name: JDW & JCM

Scan Settings (1 Range)

Final Measurement

Detectors: QP, AV

Peaks: 25

Meas Time: 1s

Acc. Margin: 6dB

Final Measurement Results

Frequencies

Receiver Settings

Start

Stop

Step

Res BW

M-Time

Atten

Preamp

150kHz

30MHz

4.5kHz

9kHz (6dB)

10ms

Auto

Off

Trace

Frequency

(MHz)

Level

(dB

V)

Limit

(dB

V)

Delta Limit

(dB)

Delta Ref

(dB)

Comment

1QP

0.15

62.42

66.00

-3.58

N/on

2AV

0.15

51.27

56.00

-4.73

N/on

1QP

0.546

47.18

56.00

-8.82

N/on

* = Limit Exceeded

1 MHz

10 MHz

150 kHz

30 MHz

10.0

20.0

30.0

40.0

50.0

60.0

70.0

0.0

80.0

dB

ȝV

Limits

55022MQP

55022MAV

Transducer
ENV216

Traces

PK+

AV

Figure 24. Conducted EMI