7.2

Flyback Transformer

The flyback transformer stage is a quasi-resonant current-regulated DC-DC Converter capable of delivering the
highest possible efficiency at a constant current while minimizing line frequency ripple. The auxiliary winding is used
for zero-current detection and overvoltage protection.

Figure 11. Flyback Transformer Schematic

7.2.1

Electrical Specifications

Characteristics conditions:

• Operating temperature range: -25 °C to +120 °C (including coil heat)

Notes:

8. Time = 2sec.
9. Measured across pins 3 and 4.

10. Measured across pins B and A.
11. Measured across pins 2 and 1.

Parameter

Condition

Sym

Min

Typ

Max

Unit

Flyback Transformer
Electrical Strength

(Note 8)

f

operate

=50/60Hz

-

4K

-

V

RMS

Primary Inductance

(Note 9)

f

resonant

=10kHz, 0.3V at 20°C

L

P

2.79

3.1

3.41

mH

Primary Leakage Inductance

(Note 9)

f

resonant

=10kHz, 0.3V at 20°C

L

K

-

-

15

H

Primary DC Resistance

(Note 9)

t

DCR

=20°C

2.175

2.90

3.625

Secondary DC Resistance

(Note 10)

t

DCR

=20°C

-

-

0.22

Auxiliary DC Resistance

(Note 11)

t

DCR

=20°C

0.3975

0.53

0.6625

36T

# 35AWG
(0.14mm)

52T

#35 AWG
(0.14 mm)

13 T

# 35AWG

(0.14mm)

Primary

4

5

3

1

Auxiliary

2

Secondary

13T

#32AWG

(0.20mm) × 2

B

A