3. Specifications

Long-term stability

Manual zero adjustment (standard)

At 1,000 and 2,000 Pa: ±8 Pa

At 5,000 and 7,000 Pa: ±24 Pa

Automatic zero adjustment (option)

±1 Pa

Maximum working pressure

25 kPa

Permissible temperature

Ambient:

-20 … +70 °C

Operation: -5 … +50 °C

Permissible ambient humidity

0 ... 95 % rH, non-condensing

Ingress protection

IP 54 per EN 60529 / lEC 529

Standards

CE conformity:

2004/108/EG Electromagnetic compatibility (EMC)

2002/95/EC RoHS (restriction of the use of certain hazardous

substances in electrical and electronic equipment)

For further specifications see WIKA data sheet SP 69.04 and the order