WIKA operating instructions mini limit switch, model LSO.02

13334591.02 10/2010 GB/D/F/E

GB

6. Commissioning, operation / 7. Maintenance and cleaning

6.2 Mechanical installation of the Mini Limit Switch

Mount the mini limit switch, pressure tight, into the process connection. The distance

between sensor-tip and opposite surface of the pipe should be greater than 10 mm. If the

pipe is electropolished, the distance should be increased accordingly.

6.3. Electrical connection of the mini limit switch

The sensor must be connected as shown in the connection diagram.

Electrical connection diagram

Connector assignment

Output

Output

brown

green

white

O. C. pnp

Load

Switching direction

The switching direction is factory set:

Model Function Condition LED

Output transistor Ext. relay

SE

Normally

open

immersed

on

switch on

connect

SE

Normally

open

not immersed off

switch off

disconnect

SA

Normally

closed

immersed

off

switch off

disconnect

SA

Normally

closed

not immersed on

switch on

connect

7. Maintenance and cleaning

7.1 Maintenance

As a rule, the Mini Limit Switch is maintenance-free.

If the plant is subject to heavy contamination or scale, it is advisable to set up periodic

maintenance. This depends on the optical condition of the glass tip and the switch

operation.

Repairs must only be carried out by the manufacturer.