2. Safety / 3. Specifications

To ensure safe working on the instrument, the operating company must ensure

„

that suitable first-aid equipment is available and aid is provided whenever

required.

„

that the operating personnel are regularly instructed in all topics regarding

work safety, first aid and environmental protection, and know the operating

instructions, in particular the section on safety instructions.

DANGER!

Danger of death caused by electric current

Upon contact with live parts, there is a direct danger of death.

„

The instrument may only be installed and mounted by skilled personnel.

„

Any connection work may only be carried out once the equipment has been

isolated.

„

Operation using a defective power supply unit (e.g. short circuit from the

mains voltage to the output voltage) can result in life-threatening voltages at

the bimetal temperature switch!

WARNING!

Residual media in the dismounted instrument can result in a risk to persons, the

environment and the equipment. Take sufficient precautionary measures.

Do not use this instrument in safety or Emergency Stop devices. Incorrect use of

the instrument can result in injury.

Should a failure occur, aggressive media with extremely high temperature and

under high pressure or vacuum may be present at the instrument.

3. Specifications

Temperature ranges

„

Nominal Switching Temperature (NST)

50 ... 200 °C
Note:

The nominal switching temperature can be selected in steps of 5 K. It is preset on

delivery and cannot be changed.

„

Switch point accuracy

±5 K