WIKA 432.36 User Manual
Page 8

8
2080276.04 12/2010 GB/D/F/E
GB
WIKA operating instructions pressure gauge model 4 per ATEX
3. Specifications
Pressure limitation
Model 43X.50/30: Steady:
full scale value
Fluctuating: 0.9 x full scale value
Short time: 5 x full scale value, however max. 40 bar
Model 43X.36/56: Steady:
end value of measuring range
Fluctuating: 0.9 x end value of measuring range
Short time: 40, 100 or 400 bar
Temperature effect
When the temperature of the measuring system deviates from the reference
temperature (+20 °C): max. ±0.8 %/10 K of full scale value
IP Ingress protection
IP 54 per EN 60529 / IEC 529
(with liquid filling IP 65)
For further specifications see WIKA data sheet PM 04.03, PM 04.07 and the
order documentation.
4. Design and function
Description
Nominal size 100 and 160 mm
The instruments measure the pressure by means of resilient diaphragm
measuring elements
The measuring characteristics are in accordance with the EN 837-3 standard
In addition, the enclosing and the pressurised components of models 43X.30
and 43X.36 also meet the requirements of EN 837-1, relating to safety pressure
gauges with a solid baffle wall (code S3).
Scope of delivery
Cross-check scope of delivery with delivery note.
5. Transport, packaging and storage
5.1 Transport
Check pressure gauge for any damage that may have been caused by transport.
Obvious damage must be reported immediately.