Safety – WIKA 233.50 User Manual

Page 7

background image

GB

2080268.06 02/2013 GB/D/F/E

WIKA operating instructions pressure gauge, model 2 per ATEX

7

2. Safety

current standards and directives, are capable of carrying out the work

described and independently recognising potential hazards.

2.3 Safety instructions for pressure gauges per ATEX

WARNING!

Non-observance of these instructions and their contents

may result in the loss of explosion protection.
WARNING!

It is imperative that the application conditions and safety

requirements of the EC-type examination certificate are

followed.

„

Pressure gauges must be earthed via the process

connection!

Specifications
Permissible temperatures
Ambient: Model 232/262 -40 ... +60 °C

Model 233/263 -20 ... +60 °C (glycerine filling)

-40 ... +60 °C (silicone oil filling)

Medium: The permissible medium temperature not only depends on

the instrument design, but also on the ignition temperature

of the surrounding gases, vapours or dusts. Both aspects

have to be taken into account.

For maximum permissible medium temperatures see table 1.

Attention! In the case of gaseous substances, the temperature may

increase due to compression warming. In these cases it may be neces-

sary to throttle the rate of change of pressure or reduce the permissible

medium temperature.