Specifications model c-2, Wiring – WIKA C-2 User Manual
Page 5
OI C-2 GB/D/F/E 01/2010
8 WIKA Operating instructions/Betriebsanleitung/Mode d'emploi/Instrucciones de servicio C-2
OI C-2 GB/D/F/E 01/2010
9
WIKA Operating instructions/Betriebsanleitung/Mode d'emploi/Instrucciones de servicio C-2
Specifications
Model C-2
Pressure ranges
bar
6
10
12
16
30
60
Over pressure safety
bar
20
20
40
40
100
100
Burst pressure
bar
25
25
50
50
120
120
All pressure ranges also from -1 bar available.
{Vacuum, gauge pressure, compound range are available}
Materials
Wetted parts
Brass, ceramic Al2O3 96 %
O-ring: CR70 (chloroprene)
Case
Brass
Electronics
Signal output
Power supply U
B
Load R
A
4 ... 20 mA, 2-wire
7 ... 30 VDC
R
A
≤ (U
B
– 7 V)/0.02 A
1 ... 5 V, 3-wire
8 ... 30 VDC R
A
> 5 kOhm
0 ... 10 V, 3-wire
14 ... 30 VDC
R
A
> 10 kOhm
0.5 ... 4.5 V, ratiometric
5 ± 0.5 VDC
R
A
> 4.5 kOhm
Response time (10 … 90 %)
ms
≤
5
Insulation voltage
VDC
500
Accuracy
% of span ≤
2.0
*)
*)
Including non-linearity, hysteresis, zero point and full scale error
(corresponds to error of measurement per IEC 61298-2).
Long-term drift
% of span
≤ 0.3 according to IEC 61298-2
Permissible temperature of
Medium
-20 ... +80 °C
-4 ... +176 °F
Ambience
-25 ... +85 °C
-13 ... +185 °F
Storage
-25 ... +80 °C
-13 ... +176 °F
Rated temperature range
-25 ... +80 °C
-13 ... +176 °F
CE- conformitiy
EMC directive
2004/108/EC, EN 61 326 Emission (Group 1, Class B) and
Immunity (industrial locations)
Wiring
Circular connector
M12x1, 4-pin
Connector Metri Pack
Series 150, 3-pin
Flying leads,
1 m / 2 m
2-wire
UB = 1 0V = 3
UB = B 0V = A
UB = brown 0V = green
3-wire
UB = 1 0V = 3 S+ = 4 UB = B 0V = A S+ = C UB = brown 0V = green
S+ = white
Wire gauge
-
3 x 0.14 mm2
Cable diameter
-
3.2 mm
Ingress Protection
per IEC 60 529
IP 67
IP 67
IP 69K
The ingress protection classes specified only apply while the pressure transmitter is
connected with female connectors that provide the corresponding ingress protection.
7. Starting, operation
GB
UB/S+ Positive supply / measurement connection
0V
Negative supply / measurement connection
7. Starting, operation
GB