beautypg.com

Specifications model c-2, Wiring – WIKA C-2 User Manual

Page 5

background image

OI C-2 GB/D/F/E 01/2010

8 WIKA Operating instructions/Betriebsanleitung/Mode d'emploi/Instrucciones de servicio C-2

OI C-2 GB/D/F/E 01/2010

9

WIKA Operating instructions/Betriebsanleitung/Mode d'emploi/Instrucciones de servicio C-2

Specifications

Model C-2

Pressure ranges

bar

6

10

12

16

30

60

Over pressure safety

bar

20

20

40

40

100

100

Burst pressure

bar

25

25

50

50

120

120

All pressure ranges also from -1 bar available.
{Vacuum, gauge pressure, compound range are available}

Materials

„

Wetted parts

Brass, ceramic Al2O3 96 %

O-ring: CR70 (chloroprene)

„

Case

Brass

Electronics

Signal output

Power supply U

B

Load R

A

4 ... 20 mA, 2-wire

7 ... 30 VDC

R

A

≤ (U

B

– 7 V)/0.02 A

1 ... 5 V, 3-wire

8 ... 30 VDC R

A

> 5 kOhm

0 ... 10 V, 3-wire

14 ... 30 VDC

R

A

> 10 kOhm

0.5 ... 4.5 V, ratiometric

5 ± 0.5 VDC

R

A

> 4.5 kOhm

Response time (10 … 90 %)

ms

5

Insulation voltage

VDC

500

Accuracy

% of span ≤

2.0

*)

*)

Including non-linearity, hysteresis, zero point and full scale error

(corresponds to error of measurement per IEC 61298-2).

Long-term drift

% of span

≤ 0.3 according to IEC 61298-2

Permissible temperature of

„

Medium

-20 ... +80 °C

-4 ... +176 °F

„

Ambience

-25 ... +85 °C

-13 ... +185 °F

„

Storage

-25 ... +80 °C

-13 ... +176 °F

Rated temperature range

-25 ... +80 °C

-13 ... +176 °F

CE- conformitiy

„

EMC directive

2004/108/EC, EN 61 326 Emission (Group 1, Class B) and

Immunity (industrial locations)

Wiring

Circular connector

M12x1, 4-pin

Connector Metri Pack

Series 150, 3-pin

Flying leads,

1 m / 2 m

2-wire

UB = 1 0V = 3

UB = B 0V = A

UB = brown 0V = green

3-wire

UB = 1 0V = 3 S+ = 4 UB = B 0V = A S+ = C UB = brown 0V = green

S+ = white

Wire gauge

-

3 x 0.14 mm2

Cable diameter

-

3.2 mm

Ingress Protection
per IEC 60 529

IP 67

IP 67

IP 69K

The ingress protection classes specified only apply while the pressure transmitter is
connected with female connectors that provide the corresponding ingress protection.

7. Starting, operation

GB

UB/S+ Positive supply / measurement connection
0V

Negative supply / measurement connection

7. Starting, operation

GB