NOTe: MINIMUM CLeARANCe FOR

SINgLe WALL STOVePIPe IS 18 INCHeS.

FOR DVL PIPe, THe MINIMUM IS 8

INCHeS.

exTeND-A-CAP ASSeMbLY

MINIMUM

CLeARANCe:

(NOTe beLOW)

COMbUSTIbLe WALL

THIMbLe ASSeMbLY

PIPe (AS ReqUIReD)

RIgID PIPe

SPACeR

RIgID Tee

ACCeSS DOOR

(FOR CLeANINg)

1 INCH AIR gAP

10

Adjustable Sleeve until the base of the Wall

Pass Through is flush against the masonry

(Fig.17) NOTE: The Wall Pass Through

must protrude a minimum of 2" into the

room (Fig.16).

Attach the 10" Long Rigid Pipe Section to the

front of the Wall Pass Through with four sheet

screws through the L-brackets (Fig.15, Fig.16)

Position the appliance, at it’s final location.

STEP FOUR: Push the Adjustable Sleeve from

the Wall Pass Through into the branch of the

tee. Connect Adjustable Sleeve to Tee branch

with the pre-formed buttons. Recommended

to grout in place with a high temperature grout

(Fig.15, Fig.16).

STEP FIVE: Slide the Wall Pass-Through

through the square trim plate and into the

Figure 15