Kramer Electronics 466 User Manual
Page 12
Cascading Machines
9
5.1 Using Additional 466 Machines
You can connect additional
466 units (operating as receivers) to further
extend the output signal range.
To use additional
466 machines, do the following:
1. Connect the required outputs
1
to the newly added
466 receiver unit.
2. Connect the TWISTED PAIR OUT 1 and/or OUT 2 detachable terminal
blocks of the previously connected unit, to the TWISTED PAIR IN
detachable terminal block on the newly added unit, using a shielded
twisted pair cable.
3. Push in the TWISTED PAIR/LOCAL button on the new machine, to the
TWISTED PAIR position
2
.
4. Set the MODE SELECT switch button on each
466 unit to PROF. or
CONSUMER, as required (see Figure 2)
5. Press one of the LOCAL INPUT SELECTOR buttons to select an input
source
3
.
This source will appear on all outputs simultaneously
When connecting several machines, push in the TWISTED PAIR/LOCAL button
on all receiver units, except for the transmitter unit.
1 You do not have to connect all the outputs
2 Push in the TWISTED PAIR/LOCAL button on each unit except for the first machine (to which the inputs are connected).
3 If the valid digital audio signal is present on the selected input, the green LINK LED will light