FC-10ETH - Configuring the FC-10ETH Ethernet Controller
To configure the FC-10ETH to the Passive mode, connect it and do the following:
Only for V.1 devices because this is the default mode. V.2 has no configuration.
1. Press the Search button to find the device connected to the PC.
2. Set the IP address number according to your network requirements.
3. For V1 devices, clear the Active Mode check box (if selected) in the
configuration manager. (This does not appear for V2 devices).
4. Press the Config button to accept changes.
4.4.2
The Active Routing Mode for V1 Devices Only
In the Active routing mode (V1 devices only), the FC-10ETH does not wait for the
remote station to send the connection request first, it sends the connection request
and routes the data in the destination device direction as soon as there is data to
be sent. The data is always sent to a specific destination (as defined by the
Destination IP address and the Destination Port Number Settings of the
FC-10ETH).
To configure the FC-10ETH to the Active mode, connect it and do the following:
1. Press the Search button to find the device connected to the PC.
2. Set the IP address number according to your network requirements.
3. Select the Active Mode check box in the configuration manager.
4. Set the Destin. IP and Port in the Destination Settings Area, for CHANNEL 1
and CHANNEL 2.
5. Press the Config button to accept changes.