Installation Instructions

Hi-O Overview

Prepare Strike

Prepare Frame

1. Prepare frame using the appropriate

template for your lockset and faceplate

combination (see page 8).

2. Connect to system using electrolynx

connectors (see page 3).

3. Install the HT1006 strike body into the

door frame.

4. Set up the Hi-O system (see pages 5-7).

1. Evaluate opening and reset Dip Switch if needed

(see Adjustment Instructions on page 4).

2. For available faceplate options,

see page 9.

ASSA ABLOY’s standard-based Hi-O system—Highly

Intelligent Opening—connects electronic door com-

ponents together over a CAN (Controller Area

Network) data network, allowing them to communi-

cate and monitor the health of the opening. Intelli-

gence is built into each device instead of one central-

ized logic unit, creating a plug-and-play system. Each

device is instantly recognized when plugged into the

system—similar to what happens when a USB device is

plugged into a computer. Every unit is connected with

a four-wire cable and has ElectroLynx® plug-in

connectors for quick installation.

Hi-O is based on devices with built-in intelligence and

a CANbus that links all the devices together. Data

traffic on the Hi-O CANbus can be encrypted. Each

Hi-O device (such as a push plate, electric strike, card

reader, door operator, etc.) is connected to the

CANbus through a single, four-wire cable. Two of the

wires supply power and the other two are used for

data communication.

Refer to the Hi-O Systems Manual (A8002).