beautypg.com

Software setup, 5 other fastbuild utility commands, Select the replacement drive. press

Page 91

background image

91

5. SOFTWARE SETUP

ASUS A7V133 User’s Manual

5. S/W SETUP

RAID

5.4.5 Other FastBuild Utility Commands

Command options 3-6 on the FastBuild™ Utility Main Menu are not required for
setting up an array, but they are useful for modifying or reconfiguring an array:
View Array (3): View the drive assignments of hard disks in an array.
Delete Array (4): Deletes an array to reconfigure the system. Deleting an array
does not remove information on the hard disks. If an array is deleted by mistake,
recover it immediately by redefining it as the deleted array.
Rebuild Array (5): This command restores the array and system data after faults on
RAID 1 arrays. Follow the steps below to rebuild and restore data in the array:
1. On boot-up, an error message notifies of a system failure.
2. Press keys to enter the FastBuildMain Menu.
3. Select <3> for View Array to verify the ID of the defunct hard disk.
4. Power off the system and replace the hard disk with an identical model.
5. Reboot and enter the FastBuildMain Menu again.
6. Select <5> for Rebuild Array. The malfunctioning array is highlighted.
Press to select it:

FastBuild (tm) Utility 1.31 (c) 1996-2000 Promise Technology, Inc.

[ Keys Available ]

[ ] Up [ ] Down [ESC] Exit [Enter] Select

[ Rebuild Array Menu ]

Array No RAID Mode Total Drv Capacity Status

Array 1 Mirror 2 1628 Critical

Array 2 ----- ----- ----- -----

Array 3 ----- ----- ----- -----

Array 4 ----- ----- ----- -----

FastBuild (tm) Utility 1.31 (c) 1996-2000 Promise Technology, Inc.

[ Keys Available ]

[ Select Drive for Rebuild ]

[ ] Up [ ] Down [ESC] Exit [Enter] Select

[ Rebuild Array Menu ]

Array No RAID Mode Total Drv Status

Array 1 Mirror 2 Critical

Stripe Block: Not Available

Channel: ID

Drive Model

Capacity (MB)

1: Slave

ST3322IA

3077

7. Select the replacement drive. Press :

This manual is related to the following products: