beautypg.com

Technical specifications, Ak m80/86 specifications, Physical – APTech Series AK M86 User Manual

Page 5: Pressure and flow, Ak m80/86 facility requirements

background image

AK M80/86 Manual

P/N 00-15000010 Rev 3

3. TECHNICAL SPECIFICATIONS

3.1.

AK M80/86 Specifications

3.1.1. Physical

ƒ Dimensions are approximately 6 inch wide by 10 inch high by 8-1/2 inch deep

ƒ Weight is approximately 9 lbs.

ƒ Mounting is by 4 each 1/4 inch diameter screws

3.1.2. Pressure and Flow

ƒ 3500 psig maximum inlet pressure

ƒ 250, 150, 100, 60, or 30 psig maximum outlet pressure options (specified when ordered)

ƒ 75 slm nitrogen maximum flow at 200 psig minimum inlet pressure (depending on line regulator

outlet pressure setting)

3.2.

AK M80/86 Facility Requirements

The following is needed to install the AK M80/86 manifold at the users facility.

ƒ Horizontal strut channel or wall with anchor bolts

ƒ 1/4 inch diameter, hex head type screws (1/4-20 or 1/4-28 thread acceptable)

The following is required for proper operation of the equipment:

ƒ Check valve for installation between cylinder and regulator inlet port

ƒ Manual valve for installation between cylinder and check valve

ƒ Appropriate purge and vent system for hazardous gases

ƒ Relief valve for installation on crossover regulator low pressure port

ƒ Relief valve for installation on line regulator low pressure port

Page 5 of 14