APTech Series AK M60 User Manual
Page 11

AK M60 Manual
P/N 00-15000012 Rev 1
Page 11 of 13
Disconnect depleted Source A cylinder and connect full cylinder.
Open Source A (left) cylinder valve and manual valve between Source A (left) cylinder and AK M60
crossover manifold. Pressure on Source A (left) gauge should indicate the full cylinder pressure.
AK M60 Model
Source A Depletion
Pressure, psig
AK M6010
85
AK M6015
135
AK M6025
225
Table 3. Approximate Source A Cylinder Depletion Pressure