11. Insure slide movement is smooth inside
12. Install ALL flanges: Starting with the inlet (30) *Verify orientation of plates(34)*. Then Proceed to tilting the

regulator so that the inlet(30) flange is laid down to prevent the PRESSURE SEALS(6, 7) from falling when
installing the vent(30) flange.

13. Tighten bolts (29) on all flanges to 192-240 in-lbs
14. Place spring housing assembly(19) into place and tighten the spring housing screws (20) to 50-100in-lbs
15. Turn handle(27) all the way in (preload compression spring 3-4 turns clockwise)
Assembly is complete


9.0 TRANSPORT / STORAGE

Severe shock and vibration should be avoided during transport. Store it in a clean and dry environment.
Regulator is ready for operation upon delivery. The protective port plugs should not be removed until
immediately before plumbing the regulator. To avoid damaging regulator or/and pilot motor, do not lift or
carry by the handle.

It is recommended to transport it with the lifting equipment suitable for the weight to be moved. Do not hook-up
lifting equipment to accessory such as handle, or pressure bores. When using a suspension belt it must be
placed around the regulator body, providing edge protection and ensuring weight distribution. Transport/storage
temperature is recommended to be between -40° C (-40° F) to +93°C (200°F). Protect existing sealing surface

10.0 DISPOSAL/RETURNS

Regulator that has come in contact with health – threatening media must be decontaminated prior to disposal or
returned to Barksdale.

Follow proper Federal/ State and local regulations for appropriate disposal to protect the environment.