SYMPTOM
Fan will not start

SOLUTION

Allow a 24-hour "break in" period. Most noises

associated with a new fan will go away
during this time.


Make sure all blade attachment screws are

tight.


Make sure outlet box is secured to building

structure, if necessary use the wood screws
provided to further secure outlet box to joist.


Make sure hanger bracket is secure to the

outlet box, screws are tight.

SYMPTOM

Fan Wobble

SOLUTION

NOTE: All blade sets are grouped by weight.

Because wood and plastic blades vary in
density, the fan may wobble even though
blades are matched.

Make sure all blade attachment screws are tight.
Make sure outlet box is secured to building

structure, if necessary use the wood screws
provided to further secure outlet box to joist.

Make sure hanger bracket is secure to the outlet

box, screws are tight.

Use the balancing kit provided if the wobble is

excessive (follow instructions included with
balancing kit)

TROUBLESHOOTING

SYMPTOM
Fan will not start

SOLUTION

Check to make sure the wall switch is turned on.
Check circuit fuses or breakers.
Caution! Make sure the power is turned off
before performing the following steps.
Remove canopy and check wire connections.
If using a remote controlled fan; check to see
that the deep switches from transmitter and
receiver are set to the same frequency code.
Check wall control transmitter connections (if
applicable).
Note: Fan must be installed from a maximum
distance of 40 feet from the transmitting unit
for proper signal transmission between the
transmitting unit and the fan's receiving unit.