beautypg.com

Quick Cable 800 Amp Booster Clamps Cable Assembly and Safety User Manual

Booster clamps

background image

Items not included in the booster cable kit: copper cable and heavy wall copper lugs.

2. Cut cable to the length of the booster cables you desire. This cable should either be twin conductor or two separate

conductors, one for the positive and one for the negative. We strongly recommend finely stranded welding-type

cable, with a neoprene or synthetic rubber insulation, as this will remain flexible in cold weather and give you maxi-

mum conductivity. See #5 (page 2)

3. Red for Positive, Black for Negative. Use red insulated or red marked cable for the positive booster cable and use

black insulated cable for the negative booster cable.

4. Length and Gauge. Generally, the longer the booster cables, the larger the gauge cable you need to use. Likewise,

the larger the displacement of the engine you are jump-starting, the larger the gauge cable you should use. If you

expect to use the booster cables in very cold conditions, where the temperature may be below 0° F or –20° C, use a

large gauge cable, as batteries will not be operating at their peak capability.

These instructions are designed for the professional mechanic who

wishes to make or repair a set of booster cables using 800 amp booster

clamps, Nos. 602070-002, 602071-001 and 602072-001.

These booster clamps can be used with 1, 1/0, 2/0, and 3/0 gauge

cable. The gauge of the cable you select is dependent on two factors, the

length of your booster cable and the amperage draw of the equipment

you are jump-starting.

Once you have selected the cable gauge, then you know which No.

4800 series heavy wall copper lugs you should use. These booster clamps

are made to be used with 1, 1/0, 2/0, or 3/0 gauge heavy wall copper lugs. The lugs are not included with the booster

clamps; they should be purchased separately. See #6 page 2
1. No. 602070-002 booster clamp kits contain the following:

No. 602071-001 Kit

1 – 800 amp Solid Copper Clamp
2 – 3-3/4” (95mm) Handle Grip Tube - Black
1 – 5/16” - 18 x 5/8” Round Head Screw
1 – 5/16” - 18 Hex Nut

No. 602072-001 Kit

1 – 800 amp Solid Copper Clamp
2 – 3-3/4” (95mm) Handle Grip Tube - Red
1 – 5/16” - 18 x 5/8” Round Head Screw
1 – 5/16” - 18 Hex Nut

8

80

00

0 A

Am

mp

p B

Bo

oo

os

stte

err C

Clla

am

mp

ps

s

C

Ca

ab

blle

e A

As

ss

se

em

mb

blly

y a

an

nd

d S

Sa

affe

etty

y IIn

ns

sttrru

uc

cttiio

on

ns

s

Battery Efficiency and Starting Power Requirements Depend on Temperature

Temperature

Degrees F

32° F

26° C

0° C

-20° C

-29° C

100 %

65 %

40 %

18 %

100 %

155 %

210 %

268 %

0° F

-20° F

Starting Power

Available from Battery

Starting Power

Required by Engine

80° F

Temperature

Degrees C

How to Make Booster Cables Using

800 Amp Booster Clamps

No. 602070-002 Kit

2 – 800 amp Solid Copper Clamp
2 – 3-3/4” (95mm) Handle Grip Tube - Red
2 – 3-3/4” (95mm) Handle Grip Tube - Black
2 – 5/16” - 18 x 5/8” Round Head Screw
2 – 5/16” - 18 Hex Nut

Booster Clamps

Engineered by: