Maintenance & Repair

1. Make sure the HawkJaw is off

the drill pipe connection and in
the rest position on the derrick.

2. Shut down the Hydraulic

power unit.

3. Press the Grip button

repeatedly to bleed hydraulic
pressure.

4. Disconnect the Air power

supply.

5. Push in the "E" stop.
6. Assume that there is still a load

on every actuator. Proceed with
caution.

Wrench Maintenance

Tools Required

Grease gun

Grease Once per Trip

Initial Steps

Die Pivot Blocks

1. Pump grease fittings D1-D2 on

the Top wrench (TW), Middle
Wrench (MW), and Bottom
Wrench (BW).

NOTE

Consistent lubrication of the
wrenches increases performance and
component life.

BW

MW

TW

D1

D2