General information – Dow THERMAX Light Duty User Manual
Page 2
Remaining wall area
1. Fasten base section of PVC interlocking system to
concrete or masonry wall through holes provided
at 12" o.c. with pneumatic nailer or equivalent.
2. Adjust base strip to insulation board to allow for
correct width. Align each PVC section 1/8" from the
insulation board, mark and attach.
3. Apply beads of construction-grade adhesive to the
concrete centered 16" o.c. between the PVC strips.
4. Press boards firmly into position between the base
strips. Allow curing time according to adhesive
manufacturer’s recommendation.
5. Apply a continuous bead of sealant along the face
of the boards next to the joint.
6. Guide the top PVC section along the insulation board
until it snaps into the interlocking system base
(Figure 3).
installation information . commercial . united states
®™Trademark of The Dow Chemical Company (“Dow”) or an affiliated company of Dow
Printed in U.S.A.
Form No. 179-04634-1011MCK
McKAY210953
NOTICE: No freedom from any patent owned by Dow or others is to be inferred. Because use conditions and applicable laws may differ from one location to another and may change with time, Customer is responsible for
determining whether products and the information in this document are appropriate for Customer’s use and for ensuring that Customer’s workplace and disposal practices are in compliance with applicable laws and other
government enactments. The product shown in this literature may not be available for sale and/or available in all geographies where Dow is represented. The claims made may not have been approved for use in all countries
or regions. Dow assumes no obligation or liability for the information in this document. References to “Dow” or the “Company” mean the Dow legal entity selling the products to Customer unless otherwise expressly noted. NO
EXPRESS WARRANTIES ARE GIVEN EXCEPT FOR ANY APPLICABLE WRITTEN WARRANTIES SPECIFICALLY PROVIDED BY DOW. ALL IMPLIED WARRANTIES INCLUDING THOSE OF MERCHANTABILITY AND FITNESS
FOR A PARTICULAR PURPOSE ARE EXPRESSLY EXCLUDED.
Dow Polyisocyanurate Insulation
CAUTION: This product is combustible and shall only be used as specified by the local building code with respect to flame spread classification and to the use of a suitable thermal barrier. For more information, consult MSDS,
call Dow at 1-866-583-BLUE (2583) or contact your local building inspector. In an emergency, call 1-989-636-4400.
WARNING: Rigid foam insulation does not constitute a working walkable surface or qualify as a fall protection product.
Building and/or construction practices unrelated to building materials could greatly affect moisture and the potential for mold formation. No material supplier including Dow can give assurance that mold will not develop in any
specific system.
www.thermaxbydow.com
Technical Information
1-866-583-BLUE (2583)
Sales Information
1-800-232-2436
THE DOW CHEMICAL COMPANY
200 Larkin
Midland, MI 48674
Figure 3
Sealant
2.25"
Insulation
Board
Thickness
Two-Piece Interlocking System
Figure 2
Interlocking System and THERMAX™ Light Duty Insulation
(View looking up the wall)
GENERAL INFORMATION
• Store insulation inside or protect with a tarp to keep dry
until use. Prolonged exposure to water or moisture may
discolor the surface.
• Minor scratches and/or nicks may occur during installa-
tion. Also, the edges of the foil facer may become slightly
curled. This does not affect the product’s overall perfor-
mance.
A coat of good quality latex acrylic or latex enamel paint
can be used to touch up the boards, and no primer is
required. Follow paint manufacturer’s recommendations
for best results.
• There are two ways to cut THERMAX
™
Light Duty Insulation:
– Use a straight edge and a utility knife, cutting all the
way through the facing.
– Cut with a small handsaw.