beautypg.com

Dow THERMAX User Manual

Page 2

background image

In the U.S.

The Dow Chemical Company

Dow Building Solutions

200 Larkin Center, 1605 Joseph Drive

Midland, MI 48674

Technical Information

1-866-583-BLUE (2583)

Sales Information

1-800-232-2436

NOTICE: No freedom from any patent owned by Dow or others is to be inferred. Because use conditions and applicable laws may differ from one location to another and may change with time, Customer is responsible

for determining whether products and the information in this document are appropriate for Customer’s use and for ensuring that Customer’s workplace and disposal practices are in compliance with applicable laws

and other government enactments. The product shown in this literature may not be available for sale and/or available in all geographies where Dow is represented. The claims made may not have been approved for use

in all countries or regions. Dow assumes no obligation or liability for the information in this document. References to “Dow” or the “Company” mean The Dow Chemical Company and its consolidated subsidiaries unless

otherwise expressly noted. NO WARRANTIES ARE GIVEN; ALL IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ARE EXPRESSLY EXCLUDED.

Dow Polyisocyanurate Insulation

CAUTION: This product is combustible and shall only be used as specifi ed by the local building code with respect to fl ame spread classifi cation and to the use of a suitable thermal barrier. For more information, consult

(M)SDS, call Dow at 1-866-583-BLUE (2583) or contact your local building inspector. In an emergency, call 1-989-636-4400.
WARNING: Rigid foam insulation does not constitute a working walkable surface or qualify as a fall protection product.
Dow Polyurethane Foam Insulation and Sealants

CAUTION: These products are combustible and will burn if exposed to open fl ame or sparks from high-energy sources. Do not expose to temperatures above 240ºF. For more information, consult (M)SDS, call Dow at

1-866-583-BLUE (2583) or contact your local building inspector. In an emergency, call 1-989-636-4400.

GREAT STUFF PRO™ Insulating Foam Sealants contain isocyanate and a fl ammable blowing agent. Read the label and (Material) Safety Data Sheet carefully before use. Eliminate all sources of ignition before use. Wear

long sleeves, gloves, and goggles or safety glasses. Provide adequate ventilation or wear proper respiratory protection. Contents under pressure.

Building and/or construction practices unrelated to building materials could greatly affect moisture and the potential for mold formation. No material supplier including Dow can give assurance that mold will not

develop in any specific system.

Printed in the U.S.A.

®TM

Trademark of The Dow Chemical Company (“Dow”) or an affiliated company of Dow

Form No. 179-07774X-0714 CDP

CDP 45115

www.insulateyourhome.com

Better System

Use a compatible constructiongrade sealant
to join the factoryproduced shiplapped joint
as well as the end joints over roof or wall
framing (Figure 2). Orient the shiplapped

joint so that the exposed side has a shingle
fashion joint with the uphill lap on top
of the downhill lap. The shiplapped edge
may leave an uneven joint on the exposed
side. Taping the back side of the joint with
THERMAX

White Foil Tape will help protect

against moisture penetration and provide a
continuous surface.

FIGURE 2

Best System

Apply a compatible constructiongrade

sealant to the PVC Clip Strip and install
on exposed joint (Figure 3). Tape the back
side of the joint with THERMAX

White

Foil Tape.

In roof systems where the temperature of
the roof exceeds 150°F, it is recommended
to use two layers of THERMAX

White

Finish Insulation to separate the Clip Strip
from a roof system’s exterior metal.

FIGURE 3

FIGURE 4 – FASTENING PATTERN

Note: Space fasteners 12” o.c. for wood,
metal or concrete attachment