beautypg.com

7 hardware replacement, 1 mode switches, 7hardware replacement – Beijer Electronics iX Panel T40 EN User Manual

Page 19

background image

Hardware Replacement

7

Hardware Replacement

This section contains instructions on how to replace operator panel hardware.
Only components included in the latest bill of material and spare parts list are
allowed. See

Available Spare Parts for iX Panel T40

.

7.1 Mode Switches

The iX Panel T40 has four mode switches (DIP switches) located on the rear side
of the operator panel.

1 2 3 4

ON DIP

1 2 3 4

ON DIP

Warning:
The modes below are to be used with caution.

The mode switches have the following functions: 1=ON, 0=OFF
Each letter in “MODE” has a corresponding mode switch.

MODE

Description

0000

“Run mode” - boots CE, normal operation.

0010

System Restore, resets the file system and registry,
reinstalls the system program (OPsys_bxxx.CAB). Restores
the operator panel to factory settings.
Warning! Information can easily accidently be lost.

0100

Image Load mode (Sysload) allows upgrading of the
firmware in the operator panel.
Note: All files including the file system in the operator
panel will be deleted when upgrading with Image Loader.

1000

Service Menu mode, the service menu for the system
program is shown. Allows the user to set IP configuration,
erase the project, calibrate the touch screen etc. See
section

Service Menu

for details.

1100

Not used (run mode).

Beijer Electronics, MAEN004

19