Footswitch Inputs
Type: The type of message that will be sent. The available settings are MIDI CC, Tap Tempo,
Play, Record, Stop, Play/Stop, Arp/Seq, and Sustain.
MIDI Channel: This setting determines over which MIDI channel the messages are sent. The
available settings are Common, USB A1–A16, and USB B1–B16.
MIDI CC: If MIDI CC is the selected Type, this determines the MIDI CC number number. The
available range is 000–127.
MIDI to DIN: This determines whether or not MIDI data is sent to the MIDI Out (On) or not
(Off). MIDI data will be sent to MPK261's USB connection regardless of this setting.
Mode: This determines whether it is in Momentary Mode (sends its message only while
pressed and held, stops sending its message when released) or Toggle Mode (sends its
message continuously when pressed once, stops sending its message when pressed once
again).
Expression Pedal Input
MIDI Channel: This setting determines over which MIDI channel the messages are sent. The
available settings are Common, USB A1–A16, and USB B1–B16.
MIDI CC: This determines the MIDI CC number number. The available range is 000–127.
Min / Max: These determine the lowest (Min) and highest (Max) values. (If Min is higher than
Max, the fader's polarity will be reversed.) The available range is 000–127.
MIDI to DIN: This determines whether or not MIDI data is sent to the MIDI Out (On) or not
(Off). MIDI data will be sent to MPK261's USB connection regardless of this setting.