Send_strings, Xmodem timing commands – AMX Enhanced Master RS-232 Controller AXB-EM232 User Manual
Page 14
Programming
10
AXB-EM232 Enhanced Master RS-232 Controller
Send_Strings
This device also has some special Send_String escape sequences. If any of the three-character
combinations in the following table are found anywhere within a Send_String program instruction,
they will be treated as a command and not the literal characters.
Xmodem timing commands
The following table lists the AXB-EM232 Xmodem timing commands. Xmodem timeouts and
retries exist to accommodate potential Ethernet delays and for consistency among and within
products.
Any of the above will change timing for Axcess code download as well as firmware upgrades.
Send_String sequences
"27,17,Sends a break character of the specified length of
time.
"27,18,1"
Sets the 9 data bit to 1 for all subsequent characters
to be transmitted. Used with the 'B9MON' com-
mand.
"27,18,0"
Clears the 9 data bit to 0 for all subsequent charac-
ters to be transmitted. Used with the 'B9MON' com-
mand.
"27,19,
Inserts a delay before the next character to be
transmitted.
"27,20,0"
Unasserts RTS hardware handshake output high
(Device 2).
"27,20,1"
Asserts RTS hardware handshake output low
(Device 2).
Xmodem timing commands
'TIMEOUT XX'
Xmodem timeouts - via the Program Port (default = 10 sec.)
SEND_COMMAND SERIAL, 'XMTO XX' Over AXlink; where XX is from one to 50 seconds in 1-second
increments.
'RETRY XX'
Xmodem retries - via the Program Port (default = 5).
SEND_COMMAND SERIAL, 'XMRT XX' Over AXlink; where XX is from one to 10 in increments of one.