Power Soak 33638 SILVERWARE WASHER OWNER'S MANUAL User Manual
Page 28

28
Only a limited number of troubleshooting and repair
procedures may be performed by the facility owner or
manager. Any troubleshooting or repair that requires
the removal of fasteners or that entails electrical
service must not be attempted by anyone other than an
authorized service agency. To obtain the name of a
recommended service agent in your area, please call
the Power Soak Service Department at 816-222-2400.
Symptom
Possible cause
Remedy
Pump motor
will not run
Circuit breaker
accidentally turned off
Circuit breaker tripped
Power cord
unplugged (mobile
models so equipped)
Motor thermal
overload tripped
Start capacitor
defective (single
phase motors)
Turn breaker on
Investigate reason for tripping, e.g.
damaged wiring, undersized breaker.
CONTACT POWER SOAK SERVICE OR
AN AUTORIZED SERVICE AGENCY.
Reconnect plug
Investigate reason for overload tripping,
e.g. debris stuck in pump impeller. If debris
removal requires that you remove any
fasteners, YOU MUST CONTACT POWER
SOAK SERVICE OR AN AUTORIZED
SERVICE AGENCY. Once rectified, reset
thermal overload by pressing button on
bottom of motor junction box.
Replace capacitor. To do this, YOU MUST
CONTACT POWER SOAK SERVICE OR