22
The installation and initial operational check of the
Power Soak machine must be performed only by
licensed and certified plumbers and electricians.
Be sure to follow all applicable national and local
electrical codes when installing the electrical supply
and/or a new breaker. DO NOT connect the machine
using a power cord and plug or an extension cord of
any kind.
Please refer to the detailed installation instructions that were sent with the
Power Soak machine.
Electrical Requirements
The electrical requirements of the Power Soak machine are shown on the
serial number plate located on the front of the wash sink, adjacent to the
control panel enclosure and inside the enclosure itself.
All Power Soak machines have a single point electrical connection, and a
dedicated circuit is required.
The machine is completely pre-wired and tested at the factory, and a hard-
wired connection from an appropriate power source junction box is all that
is required.
The installer is to provide a disconnect that should be incorporated in the
fixed wiring.
Properly sized watertight conduit, fittings and parts are required, as well as
the appropriate gauge wire.
If the Power Soak machine is a “left-to-right” unit, the power source
junction box should be located at the left end of the machine. (The opposite
would be true for a “right-to-left” machine.)
Ideally, the junction box should be located on the wall directly behind the
pump motor and control panel.