Wash pump/heater will not operate – Power Soak 37099 PS-201 Owner's Manual User Manual
Page 23
![background image](/manuals/459076/23/background.png)
19
Wash Pump/Heater Will not Operate
Refer to the previous checklist under the “Facility
Owner / Manager Section” before proceeding to the
following checklist items:
Verify that LED #1 (Power On) is illuminated. If LED #1 is not illuminated,
check:
• Main power connection and wiring
• Fuse inside the control enclosure
• Bi-metallic disc switch for water temperature (switch must be closed
if water temperature is below 120°F)
• Bi-metallic disc switch for motor temperature (switch must be
closed if motor temperature is below 150°F)
Check to see that the Liquid Level LEDs #3 and #4 are illuminated when
the wash tank is filled to the waterline.
If either one or both of the lights are not illuminated:
• Clean the liquid level sensors as described in the “Preventive
Maintenance” section of this manual.
• Be sure that all connections to and from the liquid level sensors are
secure and that there is no physical damage to the wiring.
• If damage to connectors and/or wiring is found, contact Power Soak
Systems, Inc. at 800-444-9624.
If the above troubleshooting guidelines do not correct the problem, it will be
necessary to contact Power Soak Systems, Inc. at 1-800-444-9624.