Maintenance service and analysis guide – Nor-Lake Undercounter & Freestanding Refrigerators User Manual
Page 4
![background image](/manuals/459013/4/background.png)
4
9/09 133288
of the system. A brush with non-metal stiff bristles can be used to loosen particles so that they may
be removed with a vacuum cleaner. Important: Failure to keep the condenser coil clean and
clear of obstructions could result in temperature loss and damage to the compressor.
All moving parts have been permanently lubricated and will generally require no maintenance.
MAINTENANCE SERVICE AND ANALYSIS GUIDE
MALFUNCTION
POSSIBLE CAUSE
SOLUTION
Compressor will not start -
1. Service cord unplugged
1. Plug in service cord
no hum
2. Fuse blown or removed
2. Replace fuse
3. Appliance set to STOP
3. Reset thermostat
4. Wiring incorrect
4. Check wiring against the diagram
Compressor continually runs
1. Door left open
1. Check door
2. Door frequently opened
2. Determine reason and correct
3. Inadequate compressor
3. Determine reason and replace
ventilation
Water Leak
1. Clogged water discharge
1. Clean outlet
Outlet
2. Ice buildup on rear wall
2. See OPERATION above