9/09 133288

of the system. A brush with non-metal stiff bristles can be used to loosen particles so that they may
be removed with a vacuum cleaner. Important: Failure to keep the condenser coil clean and
clear of obstructions could result in temperature loss and damage to the compressor.


All moving parts have been permanently lubricated and will generally require no maintenance.

MAINTENANCE SERVICE AND ANALYSIS GUIDE

MALFUNCTION

POSSIBLE CAUSE

SOLUTION

Compressor will not start -

1. Service cord unplugged

1. Plug in service cord

no hum

2. Fuse blown or removed

2. Replace fuse

3. Appliance set to STOP

3. Reset thermostat

4. Wiring incorrect

4. Check wiring against the diagram

Compressor continually runs

1. Door left open

1. Check door

2. Door frequently opened

2. Determine reason and correct

3. Inadequate compressor

3. Determine reason and replace

ventilation

Water Leak

1. Clogged water discharge

1. Clean outlet

Outlet

2. Ice buildup on rear wall

2. See OPERATION above