Control Setting
The temperature controller is located at the back, right inside the cabinet. Adjust the
temperature to fit your needs. Turn the control clockwise for cooler temperatures and
counterclockwise for warmer temperatures. Allow the unit several hours to respond to
temperature control adjustments.

Stock

When loading the cabinet with contents, do not block the fan in the back. Blocking the
air flow may decrease performance.

MAINTENANCE

General Cleaning

Beginning with the initial installation, the interior surfaces of the cabinet should be
periodically cleaned with a solution of warm water and baking soda. This solution will
remove any odors from spillage that has occurred. The exterior of the cabinet should also
be cleaned frequently with a commercial stainless steel cleaner, glass cleaner or mild soap
solution. Do not use chlorinated cleaners on the stainless steel surfaces.

The shelving can be cleaned in a sink with a mild soap solution and a soft bristled brush.

Periodically the unit should be emptied and cleaned out. There is a drain in the floor of the
cabinet that drains to a drain hose on the back of the cabinet in the compressor
compartment. Be sure to use this drain line for cleaning out the cabinet interior.

Condenser Coil Cleaning

Prior to cleaning the condenser coil, disconnect the unit from power. Periodic cleaning of
the condenser coil will aid the heat transfer of the refrigeration system and increase its
efficiency. To accomplish this, remove the front grill from the cabinet. The condenser coil
is located behind the grill. Use a soft bristled brush to remove any dirt particles that are on
the fins of the condenser coil. (GF50 only) Use a vacuum cleaner or compressed air to
remove the loosened particles. Replace the grill and reconnect the unit to power. Failure
to clean the condenser coil can lead to performance loss and compressor failure.