Troubleshooting, Specifications – Nor-Lake AdvantEDGE Back Bar Refrigeration User Manual
Page 3
![background image](/manuals/458998/3/background.png)
09/13 Rev.G 143594
3
TROUBLESHOOTING
Problem
Remedy
Compressor will
not start
· Check the power cord and make sure it is plugged in and has power.
· Check the temperature controller. If it is in the “OFF” position,
turn it clockwise to set a desired temperature.
Poor performance
· Move the unit from direct sunlight.
· Move the unit away from heating devices.
· Install the unit in a well ventilated place,
with at least 2 inches of clearance on all sides.
· Clean the condenser if heavy dust is collected.
· Clear contents from blocking the inside air duct.
· Check the temperature controller for correct setting.
· Check the doors and be sure they are completely closed.
Unit noisy
· Install the unit on a level solid surface.
· Maintain 2 inches of clearance from the wall.
· Check for loose parts or mounting.
· Keep the tubing free from any contact to avoid rattle.
Condensation on
cabinet exterior
and/or floor
· Reduce humidity where the unit is installed.
· Check the drain line to make sure it is not disconnected inside the cabinet and it
drains into the drain pan in the compressor area.
SPECIFICATIONS*
Model
# of
Doors
# of
Shelves
Electrical Amps
NEMA Plug
HP
BTU
Capacity
Refrigerant
Capacity
12oz. cans
BB59
2
4
115/60/1
6.6
5-15P
1/3
1666
R-134a
9.8 oz.
640
BB59G
2
4
115/60/1
6.6
5-15P
1/3
1666
R-134a
9.8 oz.
640
BB69
2
4
115/60/1
6.6
5-15P
1/3
1666
R-134a
9.8 oz.
800
BB69G
2
4
115/60/1
6.6
5-15P
1/3
1666
R-134a
9.8 oz.
800
BB79
3
6
115/60/1
6.6
5-15P
1/3
1666
R-134a
9.8 oz.
920
BB79G
3
6
115/60/1
6.6
5-15P
1/3
1666
R-134a
9.8 oz.
920
BB95
3
6
115/60/1
7.2
5-15P
1/3
1666
R-134a
9.8 oz.
1160
BB95G
3
6
115/60/1
7.2
5-15P
1/3
1666
R-134a
9.8 oz.
1160