OPERATION AND MAINTENANCE

This cooler is designed to maintain your product temperature within the most desirable
range of +34°F to +38°F. You can expect this temperature with the proper temperature
control setting and in a normal environment. It is important to remember that when the
product is delivered, it must be placed inside the cooler as soon as possible to avoid
excessive warm up. If this happens, it may take many hours for the temperature to be
reduced to the desirable range.

The temperature controller is located on the inside left wall of the unit. Turn the control
clockwise for cooler temperatures and counterclockwise for warmer temperatures.
Allow the unit several hours to respond to temperature control adjustments.

There are interior lights located above each door. The lights have on/off switches on
each light.

When loading the cabinet with product, do not block the air flow path. Blocking the air
flow may decrease performance. Maintain clearance between the contents and air duct
on the inside left end for best performance.

This equipment is intended for the storage and display of non-potentially hazardous
bottled or canned product only.

Cleaning
Beginning with the initial installation, the interior surfaces of the cabinet should be
periodically cleaned with a solution of warm water and baking soda. This solution will
remove any odors from spillage that has occurred. The exterior of the cabinet should
also be cleaned frequently with a commercial stainless steel cleaner, glass cleaner or
mild soap solution. Do not use chlorinated cleaners on any surfaces.

The shelving can be cleaned in a sink with a mild soap solution and a soft bristled
brush.

Condenser Coil
Prior to cleaning the condenser coil disconnect the unit from power. Periodic cleaning
of the condenser coil will aid the heat transfer of the refrigeration system and increase
its efficiency. To accomplish this, remove the lower front grill from the cabinet. The
condenser coil is located behind the grill. Use a soft bristled brush to remove any dirt
particles that are on the fins of the condenser coil. Use a vacuum cleaner or
compressed air to remove the loosened particles. Replace the front grill and reconnect
the unit to power. Failure to clean the condenser coil can lead to performance loss and
compressor failure.