A8
The installation must be made with a connector that meets with the standard for connectors movable
gas appliances ANSI Z21.69 and a Quick-disconnect device that complies with the standard for
Quick-disconnect devices for use with gas fuel ANSI Z21.41 and addenda Z21.41a and Z21.41b. It
must also be installed with restraining (chain that came with the oven) to guard against transmission
of strain to the connector. The pipe fittings compound must be certified for gas.
The customer must install a manual shut off valve at the end of the gas supply pipe near the burner
which is approved by the American Gas Association Standard in Canada with the Canadian Gas
Association.
Exhaust: A draft hood is provided with the unit and it must be used when the chimney is directly
connected to a gas vent pipe. The exhaust pipe must be certified for use of gases.
Clean the air contained in the gas supply pipe at the installation to insure a successful firing on the
first try. The gas pipe sealing compound tightness must be verified using a solution of water and
soap prior to firing the unit.
ATTENTION
Make sure not to obstruct the overpressure opening on the gas regulator.
NOTE: If there’s any modification done to the system or change of the type of gas
used, make sure that the regulator pressure of the burner is adjusted as recommended in
this manual.
E. . To the electrician
Electrical supply installation must be in accordance with the electrical rating on the nameplate.
WARNING
The electrician must make sure that the supply cable does not come in contact
with the oven top which becomes hot.